Alby96 e384564784 fix: logging never fails a job, one backup retention, first copy after the upgrade
Owner review 2, phase 2 review findings (scheduler core).

- Log.Write caught only IOException. Microsoft.Extensions.Logging wraps
  provider failures in an AggregateException, so a log line that could not
  be written (in tests: the process-wide sink of a stopped server whose log
  folder was gone) escaped JobEngine.RunAsync's catch before the failure was
  stored: the job stayed running and the worker faulted. This was the cause
  of the intermittent JobApiTests/ArchiveModuleTests failures. Log.Write now
  drops any non-fatal sink failure, TeeLogSink keeps a line from the other
  sinks, FileLogSink drops a line it cannot write and reopens the file at the
  next one, and LoggerSink drops what the providers throw. The scheduler's
  loop relies on the same guarantee.
- The daily backup loop (RunDailyAsync, IsDue, Interval, CheckInterval) had
  no caller since the index-backup schedule replaced it; it is removed and
  the DatabaseBackups summary describes the schedule.
- The first copy after the upgrade no longer waits a day (or for 03:00):
  SystemSchedule.LastDone seeds a new row due at once when its work was last
  done a period or more before, and both hosts pass the newest copy in the
  backups folder for index-backup.
- Back up now (Settings and Archive), the copy kept before a restore and a
  backup job that keeps fewer prune to the largest Copies kept of the backup
  schedules (DatabaseBackups.KeptAsync), not a fixed three. The four
  tooltips that promised three daily copies are reworded (en, it) and their
  stale translations deleted.
- New tests for the scheduler loop itself: a tick, Wake, a pass that threw,
  and dispose during a pass.