Owner review 2, phase 2 review findings (scheduler core).
- Log.Write caught only IOException. Microsoft.Extensions.Logging wraps
provider failures in an AggregateException, so a log line that could not
be written (in tests: the process-wide sink of a stopped server whose log
folder was gone) escaped JobEngine.RunAsync's catch before the failure was
stored: the job stayed running and the worker faulted. This was the cause
of the intermittent JobApiTests/ArchiveModuleTests failures. Log.Write now
drops any non-fatal sink failure, TeeLogSink keeps a line from the other
sinks, FileLogSink drops a line it cannot write and reopens the file at the
next one, and LoggerSink drops what the providers throw. The scheduler's
loop relies on the same guarantee.
- The daily backup loop (RunDailyAsync, IsDue, Interval, CheckInterval) had
no caller since the index-backup schedule replaced it; it is removed and
the DatabaseBackups summary describes the schedule.
- The first copy after the upgrade no longer waits a day (or for 03:00):
SystemSchedule.LastDone seeds a new row due at once when its work was last
done a period or more before, and both hosts pass the newest copy in the
backups folder for index-backup.
- Back up now (Settings and Archive), the copy kept before a restore and a
backup job that keeps fewer prune to the largest Copies kept of the backup
schedules (DatabaseBackups.KeptAsync), not a fixed three. The four
tooltips that promised three daily copies are reworded (en, it) and their
stale translations deleted.
- New tests for the scheduler loop itself: a tick, Wake, a pass that threw,
and dispose during a pass.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit c5ad0c4c3f636129afe5dd1ce039185516da5621)
The desktop opened its log files with the default limits and wrote its first
line, which prunes, before Settings › Advanced › Logs were applied. Every start,
and every launch that only hands its file to the running Chronos, deleted logs
older than 14 days and cut the folder to 1 GB whatever the user kept.
AppLogging.Open now builds the sink from the stored settings before that line;
the settings are read again once the launch owns the data folder.
A total below one file deleted each finished file as the next one opened. The
rule now lives in LogFileOptions.TotalBelowFile: the server keeps refusing it,
the desktop raises the total to the file size and its rows no longer offer the
combination.
The desktop log rows threw on negative sizes from an imported or hand-edited
file and showed raw values the files never got; they now show the applied ones.
Upgraded Unraid and compose installs keep CHRONOS_LOG_LEVEL=Information, which
locks both levels. The lock stays; the server now reports which variable fixes
each locked setting (LockedBy), so the panel's tooltip names it exactly and says
to remove it to change the value there. The releases README tells upgraders.
The former-constructor log test no longer fails across midnight UTC.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit 8ba7162bd5926d34c5ec4e40e2a2dad063ee19c3)
Owner review 2, R11 asked for more log settings. The file sink now writes daily or
hourly files, continues a full file in numbered parts and prunes by age and by the
total size (never the file being written); its options change while it runs.
Server: the file and console levels are separate and read by the logging filters
at every line, so the admin panel's new Logs group applies without a restart; the
engine's level follows the lower of the two. This also fixes a bug: the file logger
was fixed at Information, so CHRONOS_LOG_LEVEL=Debug or Trace never reached the
files. New variables CHRONOS_LOG_CONSOLE_LEVEL, CHRONOS_LOG_RETENTION_DAYS,
CHRONOS_LOG_MAX_FILE_MB, CHRONOS_LOG_MAX_TOTAL_MB, CHRONOS_LOG_ROTATION,
CHRONOS_AUDIT_RETENTION_DAYS and CHRONOS_DIAGNOSTICS_LOG_MB lock their settings like
the others; the diagnostics zip keeps the configured share of each log.
Desktop: Settings > Advanced gains Log level, Keep logs, File size, Logs total,
Rotation and Diagnostics logs, applied at every save; Advanced's Reset section
restores them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit cc875784e4952ee0e4c807b9d9c18496d3d5a8c3)
The owner renamed the product and moved the repository to the self-hosted
Gitea (https://gitea.encke-hake.ts.net/BalboSoft/Chronos) for more control,
and asked for Actions and a first automatic release with the server package
and the Windows exe (docs/requests/2026-10-23-chronos-gitea.md).
- Chronos everywhere: a byte-exact rename of contents and paths, then a
per-language review of the forms the old name's ending had dictated.
- Gitea instead of GitHub: the update check, licence, issue and support
links read ChronosReleasesUrl; the update check takes the highest stable
version, offers a pre-release build its final release and reports a
repository it cannot see as a failed check. EULA, security policy and
Gitea issue forms live at the repository root.
- Gitea Actions for the Linux act_runner (.gitea/workflows): CI, release,
nightly image and performance gates in the .NET SDK container with git
checkout and the system SQLite. The release cross-compiles the Windows
programs, checks their icon, version and DPI manifest, packs installers
and zips, publishes the Gitea release and pushes the server image
(REGISTRY_TOKEN). Windows-only tests run in an opt-in job on a Windows
runner (WINDOWS_RUNNER).
- New Chronos.Tools commands: zip, gitea-release, postgres-ci (replaces the
docker-exec script, which Gitea's service containers do not allow; the
throw-away server runs without durability) and pe-check.
- Timed tests take their budget from TestTiming (CHRONOS_TEST_TIME_FACTOR,
3 on the shared runner; the weekly performance gates keep theirs).
BREAKING CHANGE: programs, settings, data folders, file types, environment
variables and the Docker image use the new name; nothing is migrated from
Titano, which never had a release.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>