fix(analysis): measure noise robustly and count only consistent flow vectors
Median-based Immerkaer noise ignores stars and edges, so star detection and the noise column no longer read star fields as noise; motion statistics keep only vectors that pass the forward-backward check. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_012iLMBNwBE2GnphAsu4cjaC
This commit is contained in:
5 files changed
+79
-16
No files matched your search
@@ -102,6 +102,8 @@ public static class DeepAnalyzer
|
||||
private sealed class SequentialState(DeepAnalysisOptions options) : IDisposable
|
||||
{
|
||||
private const int MinimumStabilizerSize = 16;
|
||||
private const float ReliableError = 0.5f;
|
||||
private const double MinimumReliable = 0.05;
|
||||
private readonly OpticalFlowEngine _flow = new(FlowQuality.Draft);
|
||||
private Stabilizer? _stabilizer;
|
||||
private FrameStatistics? _previous;
|
||||
@@ -121,6 +123,7 @@ public static class DeepAnalyzer
|
||||
frame = frame with
|
||||
{
|
||||
Flags = frame.Flags | (duplicate ? DeepFrameFlags.Duplicate : DeepFrameFlags.None),
|
||||
Noise = probe.Noise,
|
||||
ShiftX = shiftX,
|
||||
ShiftY = shiftY,
|
||||
MotionMedian = motionMedian,
|
||||
@@ -165,7 +168,6 @@ public static class DeepAnalyzer
|
||||
BlueRatio = stats.MeanBlue > 0 && green > 0 ? double.Log2(stats.MeanBlue / green) : double.NaN,
|
||||
Kelvin = stats.ColorTemperature?.Kelvin ?? double.NaN,
|
||||
Sharpness = stats.Sharpness,
|
||||
Noise = stats.Noise,
|
||||
};
|
||||
}
|
||||
|
||||
@@ -189,8 +191,12 @@ public static class DeepAnalyzer
|
||||
return ((x - cx) * probe.CorrelationScale, (y - cy) * probe.CorrelationScale);
|
||||
}
|
||||
|
||||
/// <summary>Draft flow from the previous frame with the current frame brought to the previous mean level, so
|
||||
/// flicker and exposure steps do not read as motion; magnitudes in source pixels per frame.</summary>
|
||||
/// <summary>
|
||||
/// Draft flow from the previous frame, with the current frame brought to the previous mean level so flicker and
|
||||
/// exposure steps do not read as motion. Only vectors that pass the forward–backward check (error ≤
|
||||
/// <see cref="ReliableError"/> flow pixels) count, so flat noisy areas do not either; NaN when under
|
||||
/// <see cref="MinimumReliable"/> of the vectors are reliable. Magnitudes in source pixels per frame.
|
||||
/// </summary>
|
||||
private (double Median, double P95) Motion(FrameProbe probe, FrameStatistics stats, CancellationToken cancellationToken)
|
||||
{
|
||||
if (probe.Index % options.FlowEvery != 0 || _previousIndex != probe.Index - 1) return (double.NaN, double.NaN);
|
||||
@@ -202,9 +208,25 @@ public static class DeepAnalyzer
|
||||
{
|
||||
foreach (ref var v in levelled.Data) v *= gain;
|
||||
}
|
||||
using var field = _flow.Compute(previous, levelled, cancellationToken);
|
||||
var statistics = field.Statistics();
|
||||
return (statistics.MedianMagnitude * probe.FlowScale, statistics.P95Magnitude * probe.FlowScale);
|
||||
var (forward, backward) = _flow.ComputeBidirectional(previous, levelled, cancellationToken);
|
||||
using (forward)
|
||||
using (backward)
|
||||
{
|
||||
var u = forward.U;
|
||||
var w = forward.V;
|
||||
var error = forward.Error;
|
||||
var magnitudes = new float[forward.Count];
|
||||
var count = 0;
|
||||
for (var i = 0; i < magnitudes.Length; i++)
|
||||
{
|
||||
if (error[i] <= ReliableError) magnitudes[count++] = float.Hypot(u[i], w[i]);
|
||||
}
|
||||
if (count < MinimumReliable * magnitudes.Length) return (double.NaN, double.NaN);
|
||||
var reliable = magnitudes.AsSpan(0, count);
|
||||
var median = PlaneOps.Median(reliable);
|
||||
var p95 = PlaneOps.Select(reliable, int.Max(0, (int)double.Ceiling(0.95 * count) - 1));
|
||||
return (median * probe.FlowScale, p95 * probe.FlowScale);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in new issue
Block a user